Chinese Journal of Radiology ; (12): 844-848, 2023.
Article in Chinese | WPRIM | ID: wpr-993010

ABSTRACT

Objective:To explore the optimal keV value of the virtual monoenergetic image (VMI) for displaying the osteosarcoma by using the dual-layer spectral detector CT and to evaluate its application value in determining the extent of intramedullary invasion of osteosarcoma.Methods:From August 2021 to August 2022, 57 patients with conventional osteosarcoma of long bone confirmed by biopsy in Beijing Jishuitan Hospital, Capital Medical University were retrospectively analyzed. All patients completed dual-layer spectral CT enhanced examination before limb salvage surgery, and tumor segment resection specimens were obtained after surgery. Conventional 120 kVp image and VMI of 40, 50, 60, 70 and 80 keV were obtained by spectral CT examination, and the CT values of tumors, image noise were measured and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the corresponding images were calculated. The objective evaluation among the six groups of images were assessed with the Friedman test, and then determined the optimal keV value. The maximum distance between the intramedullary boundary of osteosarcoma and the adjacent articular surfaces was measured on the best keV VMI and the tumor segment resection specimens. The Wilcoxon signed rank test was used to find the differences and the Spearman correlation analysis was used to evaluate the correlation between the distance measured from the best keV VMI and the specimens.Results:There were significant differences in CT value, image noise, SNR and CNR between 40-80 keV VMI and 120 kVp conventional CT images ( P<0.05). The CT value, SNR and CNR of 40 and 50 keV VMI were better than 120 kVp ( P<0.001). The 50 keV VMI was chosen as the best keV VMI to measure the intramedullary extent of osteosarcoma. The distance measured from 50 keV VMI was 103.9 (80.4, 131.4) mm, while the distance measured from specimens was 113.5 (94.0, 142.0) mm, and the difference was statistically significant ( Z=-5.76, P<0.001). The 50 keV VMI measurements in 51 patients were smaller than the gross specimens, which underestimated the tumor intramedullary extent, with the difference was 11.1 (6.6, 13.8) mm. The Spearman correlation analysis demonstrated a high positive correlation of distance measured on gross specimens with the 50 keV VMI ( r s=0.960, P<0.001). Conclusions:Dual-layer spectral detector CT with 50 keV VMI is the best image to show the limb osteosarcoma. Compared with gross specimens, the distance measured from CT underestimated the intramedullary invasion range of limb osteosarcoma about 10 mm, but the two show a good correlation.

2.
Acta Academiae Medicinae Sinicae ; (6): 280-284, 2023.
Article in Chinese | WPRIM | ID: wpr-981264

ABSTRACT

Objective To explore the optimal parameters for virtual mono-energetic imaging of liver solid lesions. Methods A retrospective analysis was performed on 60 patients undergoing contrast-enhanced spectral CT of the abdomen.The iodine concentration values of hepatic arterial phase images and the CT values of different mono-energetic images were measured.The correlation coefficient and coefficient of variation were calculated. Results The average correlation coefficients between iodine concentrations and CT values of hepatic solid lesion images at 40,45,50,55,60,65,and 70 keV were 0.996,0.995,0.993,0.989,0.978,0.970,and 0.961,respectively.The correlation coefficients at 40(P=0.007),45(P=0.022),50 keV (P=0.035)were higher than that at 55 keV,and the correlation coefficients at 40 keV(P=0.134) and 45 keV(P=0.368) had no significant differences from that at 50 keV.The coefficients of variation of the CT values at 40,45,and 50 keV were 0.146,0.154,and 0.163,respectively. Conclusion The energy of 40 keV is optimal for virtual mono-energetic imaging of liver solid lesions in the late arterial phase,which is helpful for the diagnosis of liver diseases.


Subject(s)
Humans , Tomography, X-Ray Computed , Retrospective Studies , Abdomen , Iodine , Liver/diagnostic imaging , Signal-To-Noise Ratio , Radiographic Image Interpretation, Computer-Assisted/methods
3.
Acta Academiae Medicinae Sinicae ; (6): 230-234, 2021.
Article in Chinese | WPRIM | ID: wpr-878725

ABSTRACT

Objective To investigate the role of dual-layer detector energy spectral CT in resting myocardial perfusion imaging for patients with normal coronary artery. Methods One hundred and fifty-six patients with suspected coronary heart disease underwent dual-layer detector energy spectral CT coronary angiography,and resting myocardial perfusion imaging was performed for 28 patients with normal coronary artery.According to American Heart Association's 17-segmentmodel,the iodine density and effective atomic number(Z


Subject(s)
Humans , Computed Tomography Angiography , Coronary Angiography , Coronary Vessels/diagnostic imaging , Myocardial Perfusion Imaging , Tomography, X-Ray Computed
4.
Acta Academiae Medicinae Sinicae ; (6): 359-363, 2020.
Article in Chinese | WPRIM | ID: wpr-826356

ABSTRACT

To evaluate the effect of monochromatic energy image on inferior vena cava imaging quality on dual-layer detector spectral CT. Totally 39 patients who were clinically suspected of abdominal disease and referred to perform contrast-enhanced computed tomography(CT)were prospectively enrolled and underwent abdominal examination using a single-source,dual-detector spectral CT.The delayed phase scan was performed 3 minutes after injection of 60 ml of iopamidol(320 mg/ml)at a rate of 3 ml/s.The raw images were reconstructed to obtain conventional mixed energy images and spectral based images(SBI).The 40,50,60,and 70 keV single energy images were obtained.The CT value,noise,and signal-to-noise(SNR)of inferior vena cava and the contrast-to-noise(CNR)of inferior vena cava relative to psoas major on conventional mixed energy images and the 40,50,60,70 keV single energy images were measured.The SNRs and CNRs on monoenergetic 40-70 keV images were compared with polychromatic 120 kVp images.ANOVA was used to compare the CT value,noise,SNR,and CNR among these five groups.The optimal monoenergetic image set was chosen. The differences in CT value,noise,SNR,CNR of inferior vena cava were statistically significant among five groups(all <0.05).The SNR and CNR in 40 keV group and 50 keV group were significantly higher than those in other groups(all <0.05).The SNR of 40 keV group was significantly higher than that of 50 keV group(=0.002).The CNR of 40 keV group was not statistical different compared with that of 50 keV group(=0.630). 40 keV is the optimal monoenergetic energy level for the inferior vena cava on dual-layer detector spectral CT and may be valuable for the diagnosis of inferior vena cava disease.


Subject(s)
Humans , Abdomen , Radiographic Image Interpretation, Computer-Assisted , Signal-To-Noise Ratio , Tomography, X-Ray Computed , Vena Cava, Inferior